Exercise Testing Tolerance when Using Face Mask
445-448
DOI:
https://doi.org/10.7775/rac.es.v89.i5.20450Keywords:
Exercise, Face mask, SARS-CoV-2 - COVID 19, Exercise testingAbstract
Background: Tolerance to exercise with the use of face mask is not well known.
Objective: The aim of this study was to investigate the tolerance of exercise parameters during exercise stress testing (EST) while wearing a face mask.
Methods: Multicenter study of EST while wearing face mask.
Results: 118 ESTs (62 on treadmill, 56 on cycle ergometer), 68 men, age 46.74 ± 16.7 years. Seventy patients (59.3%) com-
pleted the EST wearing a face mask, and 48 (40.7%) removed it; 17 patients (27.4%) were on treadmill and 31 (55.4%) on cycle ergometer (p = 0.002). Percentage of maximum predicted heart rate attained when the patients removed their face mask: 94.5 ± 5.35%. Age of those who removed the face mask: 42.69 ± 17.35 years and of those who tolerated the face mask: 49.51 ± 15.88 years (p = 0.003). Baseline SpO2 was 97.46 ± 1.01% and 96.58 ± 1.37% on peak exercise wearing face mask (p < 0.0001). SpO2 when the face mask was removed: 97.06 ± 1.35% (p <0.0001). Younger age and use of cycle ergometer were predictors of intolerance to face mask.
Conclusion: Most patients completed peak exercise with face mask. Exercise intensity was high when the face mask was removed. Oxygen saturation dropped during exercise with face mask without clinical impact.
How to cite this article:
Peidro R, Bruzzese M, Brión G, González Naya E, González R, Abalsa A, et al. Exercise Testing Tolerance when Using Face Mask. Rev Argent Cardiol 2021;89:445-448.
Downloads
Published
Issue
Section
License
Copyright (c) 2021 Argentine Journal of Cardiology

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.