Preoperative y postoperative Ecocardiographic Assessment in Patients Submitted to Ross Procedure
pp 108-117
DOI:
https://doi.org/10.7775/rac.v70i2.2944Keywords:
Ross procedure, Echocardiography, Bicuspid aortic valveAbstract
Objective
The purpose of this study was to analyze the use-fulness of preoperative and postoperative echocardiographic evaluation in patients undergo-ing Ross procedure (RP).
Methods
From May 1995 through June 2001, 117 patients(mean age 36±12 years, 77males, 40 females) were indicated RP Pulmonary autograft dysfunction was defined as =2 regurgitations, as registered by Doppler echocardiography. Candidates were studied by transthoracic echocardiography (TTE) 15 days preoperatively, by intraoperative transesophagic echocardiography (IOTEE) and by TTE postoperatively and during follow up. Treadmill exercise test and echocardiography (EE) with Bruce protocol was performed in27 patients 17.7±12months postoperatively.
Results
RP was successful in 100 patients (85.5%). Hospital mortality was 3% (3 patients). The procedure was not feasible in 17 patients (14.5%) because 7patients had bicuspid pulmonary valve, 6 had multiple pulmonary valve fenestrations >3mm ,and 3 patients (3%) had moderate to severe pulmonary failure. Twelve of 16 patients presenting pulmonary valve defects had bicuspid aortic valve (p=0.04). At 6-year follow-up the probability of not undergoing reoperation was 93% (confidence interval 86-100%). While TTE and IOTEE did not detect any pulmonary valve anatomic anomalies, they detected functional anomalies. Postoperative evaluation showed severe autograft dysfunction in5 patients (5%), and a sharp increase in the pulmonary homograft gradient in 3 patients (3%). As for the 27 patientsevaluated by EE, two subgroups could be identified: one(15 patients) showed no increase in left ventricular ejection fraction and had pulmonary homograft hemodynamic anomalies and the other (12 patients) had anormal response to exercise.
Conclusions 1. This method makes it possible to define which patients are candidates for RP and which have an absolute contraindication; 2.TTE and IOTEE did not detect pulmonary valve anatomic anomalies. 3.Autograft regurgitation and pulmonary homo-graft gradient maybe monitored by IOTEE and during follow-up, 4. EE identifies two groups with different hemodynamic profile.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Argentine Journal of Cardiology

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.